型号: | PVM-3 |
---|---|
品牌: | NORTH STAR |
原产地: | 美国 |
类别: | 电子、电力 / 仪器、仪表 / 电工仪器仪表 |
标签︰ | NORTH STAR 高压探 , PVM-3 , 高压探头 VD-60 |
单价: |
¥9000
/ 件
|
最少订量: | 1 件 |
最后上线︰2017/10/18 |
NORTH STAR 高压探头 PVM-3
美国NORTH STAR 高压探头
Voltage Probe Manual and Data
North Star Research Corporation
Standard Voltage Probe Data
High Voltage Probes Up to 400 kV
High Voltage Probes
High voltage measurements have a variety of different requirements, and our PVM series and VD series probes are designed for most of these requirements. The PVM probes are designed for wide bandwidth and ease of portability where a variety of measurements must be made. The VD series probes are designed for use at higher voltage ranges, and where physical stability is required.
PVM series probes with PVM-5 on top and PVM-10 on the bottom
The design of the probes is unique. The probe comes fully adjusted without any requirement to further adjust the probe in the field. Stray capacitances internal to the probe are factory calibrated. Stray capacitances due to proximity effects are minimized by the unique conductor placement.
Low temperature and voltage coefficient resistors and capacitors are used throughout the probe to provide maximum measurement accuracy. The probe has a r ed nylon housing, and it is filled with dielectric oil for maximum high voltage stability.
Our PVM Series probes our available with either 1000:1 or 2000:1 calibration factors at the time of order.
Voltage Probe Specifications
PVM Series Portable High Voltage Probes to 60 kV DC
PVM series high voltage probes are designed for general use, and for exceptional high frequency response. The probes have applications ranging from automotive ignition to excimer laser system measurement to EMI measurement. They are factory calibrated, and they do not require adjustment. In general the probes are for use with 1 Megohm oscilloscopes, but we also offer an optional switch which can compensate for various measurement instruments such as 10 Megohm meters as well. These units are intended for a wide range of applications where portability and ease of use are essential.
Model Number |
PVM-1 |
PVM-2 |
PVM-3 |
PVM-4 |
PVM-5 |
PVM-6 |
PVM-11 (PVM-10) |
PVM-12 |
Max DC/Pulsed V (kV) |
40/60 |
40/60 |
40/60 |
40/60 |
60/100 |
60/100 |
10/12 |
25/30 |
Max Frequency (Mhz.) |
80 |
80 |
40 |
110 |
80 |
80 |
50 |
80 |
Cable Impedance (ohms) |
50 |
50 |
50 |
93 |
50 |
50 |
50 |
50 |
DC - 2 Hz.accuracy |
<0.1% |
<0.1% |
<0.1% |
<0.1% |
<0.1% |
<0.1% |
<0.1% |
<0.1% |
2 Hz. - 200 Hz. accuracy |
<1 % |
<1. % |
<2. % |
<1. % |
<1 % |
<1 % |
<1.5 % |
<1.5 % |
200 Hz. - 5 Mhz. accuracy |
<1.5% |
<1.5% |
<3% |
<1.5% |
<1.5% |
<1.5% |
<2.% |
<2.% |
> 5 Mhz. Accuracy |
<3% |
<3% |
<4% |
<5% |
<3% |
<4% |
<4% |
<4% |
Input R/C (Megohm/pf) |
400/13 |
400/13 |
400/10 |
400/10 |
400/12 |
400/12 |
100(50)/15 |
300/7 |
Cable Length (ft./m) |
15/4.5 |
30/9 |
100/30 |
15/4.5 |
15/4.5 |
30/9 |
15/4.5 |
15/4.5 |
Standard Divider Ratio |
1000:1 |
1000:1 |
10,000:1 |
1000:1 |
1000:1 |
1000:1 |
1000:1 (100:1) |
1000:1 |
Length (inches/cm.) |
19/47 |
19/47 |
19/47 |
19/47 |
19/47 |
19/47 |
7/18 |
9/23 |
Add -2 to any PVM-1 - PVM-6 or PVM-12 part number for 2000:1 ratio
VD Series High Voltage Probes 60 to 300 kV DC